ACI HAYAT عضو مميز
تاريخ التسجيل : 27/05/2010
| موضوع: قابلوات الضغط الواطئ 6/9/2010, 08:27 | |
| SPECIFICATION .
TECHNICAL SPECIFICATION LOW VOLTAGE POWER CABLES
1- SCOPE OF TENDER: This tender includes for the manufacturing, testing packing shipping delivery ex-works, FOB & C&F of (6.0/1K) (1.2/2kV).2- GENERAL REQUIREMENTS: The material shall be of first class quality and designed for continuous satisfactory operation as continuity of supply is of prime importance and to operate satisfactorily under variation of load, voltage and short circuit of other conditions which may occur on the system provided that these variations are within the designed rating of the apparatus. The material used shall be suitable for the following climate and soil condition. 2-1 Ambient temperature Highest maximum (in the shade) 55 C for about six hours a day. Lowest minimum (-10) C. Maximum yearly average (+30) C. Maximum daily average (+40) C. 2-2 Sun temperature Black objects under sunshine attain a temperature of 80C. 2-3 Air humidity maximum 92% at 40 C minimum 12% yearly average 44% 2-4 Altitudes From sea level up to (1000 m) 3-TECHNICAL REQUIREMENT: 3-1 System Data a. Nominal voltage 400 Volts 3phases, 4 wires with neutral solidly grounded. 50 HZ 3-2 Standards the cable shall be in accordance with the latest issue of the I.E.C (particularly NOS502 & 228). 3-3 Deviations the tender shall particularly mention in his tender all deviations of his offer from the specification described in these tender documents.4-GENERAL CABLES CHARACTERISTICS: 4-1 Conductor Non-compact electrolytic annealed stranded plain circular copper conductor of high conductivity 99-9% purity. 4-2 Insulation Extruded PVC (polyvinyl chloride) according to I.E.C table. 4-3 Core colors Colored for phase identifications (Red, Yellow, blue for phase) and black neutral. . 4-4 Filler and Bedding The four core then laid up with suitable fillers to form a compact circular assembly and bedded with a layer of extruded P.V.C. 4-5 Metallic Armor (for multi-core cables) The four cores then armored with double galvanized steel tapes of thickness according to I.E.C clause 12.4. Each tape layer shall be applied in open helix with the second tape covering the gap left by the first, the gap shall be more than 25% of tape width.4-6 PVC jacket (st2 table 4 in IEC 502) Over all extruded PVC sheath water proof grey color of thickness according to IEC and across section marking of (400 Volts) in the Arabic language should be stamped each one meter cable length and chemically ant termite and pollution. Also name, year of manufacturing, voltage and cross-section in the Arabic language. 4-7 Packing The required cable length are to be supplied on sea. Worthy good quality drums of length as specified NO.5 below.5-TYPES OF CABLES 5-1 Single core cable 1-1 50mm2 5-1-2 70 mm2 5-1-3 95mm2 5-1-4 150mm2 5-1-5 240 mm2 For these cables the applicable paragraph are 4.1,4.2 and 4.6 on 250m length drums. 5-2 Four core cables -2-1 3x240+120mm2 -2-2 3x150+95mm2 -2-3 3x95+70mm2 -2-4 3x70+50mm2 -2-5 4x50mm2 -2-6 4x25mm2 -2-7 4x50mm2 For these cables, the applicable paragraphs are 4.1,4.2,4.3,4.4,4.5, and 4.6 for the cables from 240mm2 to 95mm2 on 250m good quality drums for cables from 50mm2 to 16mm2 on 1000n m drums.6- TECHNICAL INFORMATION: The tendered is requested to give the following information with the offer: 6-1 Resistance of copper per km of cable. 6-2 Inductance of copper per km of cable. 6-3 Capacitance of copper per km of cable. 6-4 Insulation resistance in M. ohns between core/screen. 6-5 Weight of copper per km of cable. 6-6 Overall weight per km of cable . 6-7 Overall diameter of cable 6-8 Type of technical treatment against termite in outer sheath.7-TESTS Cable shall be subjected to inspection and tests by our inspectors . The manufacturers shall provide facilities for any said inspection. Inspections shall be made at place of manufacturer or at international testing facilities. The supplier should provide test certification of the goods . | |
|
دكتورة.م انوار صفار Admin
تاريخ التسجيل : 04/04/2010 البلد /المدينة : bahrain
بطاقة الشخصية المجلة:
| موضوع: رد: قابلوات الضغط الواطئ 6/9/2010, 09:21 | |
| شكرا لك مهندس عباس على المعلومات القيمة | |
|
ACI HAYAT عضو مميز
تاريخ التسجيل : 27/05/2010
| موضوع: رد: قابلوات الضغط الواطئ 6/9/2010, 12:50 | |
| | |
|